Module 4- From Signals to Doses: CGM Dose Guidance
Continuous glucose monitoring, or CGM, provides glucose patterns that can inform therapy decisions across type 1 and type 2 diabetes, with or without insulin.
This module connects CGM insights with automated insulin delivery, dose guidance, and case-based therapy refinement while emphasizing safety and clinician oversight.
Section Introduction
Module 4- From Signals to Doses: CGM Dose Guidance
From glucose signals to therapy decisions
CGM adds a continuous view of glucose levels and trends to the isolated values available from self-monitoring of blood glucose. This module follows how those insights can inform therapy across diabetes types and treatment regimens.
The module examines three connected areas of clinical practice:
How CGM data connects with automated insulin delivery in type 1 and insulin-treated type 2 diabetes.
How glucose patterns can inform care in non-insulin-treated type 2 diabetes and during GLP-1 receptor agonist therapy.
How automated dose guidance can support individualized insulin titration with appropriate safety checks.
CGM metrics and individualized goals
Time in Range, or TIR, describes time within 70-180 mg/dL and complements A1C. The deck pairs TIR goals with hypoglycemia reduction and treatment burden, including different targets for older or high-risk adults.
Consider these together:
TIR in relation to the individual's clinical goals.
Time Below Range and the timing of hypoglycemia.
Fasting and post-meal patterns in the Ambulatory Glucose Profile, or AGP.
Treatment burden, confidence with titration, and comfort with technology.
AID and automated dose guidance
Automated insulin delivery, or AID, connects CGM data, a control algorithm, and an insulin pump. The module considers use in type 1 and insulin-treated type 2 diabetes, while emphasizing that hybrid systems still require attention to meal boluses and infusion sites.
Automated dose guidance supports insulin titration and dosing decisions rather than necessarily delivering insulin. The deck emphasizes CGM metrics, current insulin dosing, safety guardrails, and clinician review of significant medication changes.
Case-based therapy refinement
Gary's case illustrates basal insulin titration support; Jessica's addresses meal bolus timing and insulin-to-carbohydrate ratio adjustment during AID use. Janice's illustrates CGM-informed medication review for nocturnal hypoglycemia and a transition to non-insulin therapy. These are educational cases, not universal dosing instructions.
Help Us Learn, While Teaching You.
Your answer is anonymous, but greatly helps our analytics for understanding who we are reaching.
Video Module 4
Review how CGM patterns inform therapy across diabetes types, how AID and automated dose guidance differ, and how case-based decisions address basal insulin titration, meal bolus timing, and hypoglycemia with clinician oversight.
Faculty
Dr. Carol Wysham
Dr. Erin Cobry
Key Learning Points
Module 4- From Signals to Doses: CGM Dose Guidance
CGM Metrics for Clinical Decisions
CGM provides a continuous stream of information about glucose levels and trends, allowing review of daily patterns that isolated SMBG checks may miss. TIR complements A1C rather than replacing it.
The deck uses TIR 70-180 mg/dL goals of >70% for T1D/T2D and >50% for older or high-risk adults. TBR goals for T1D/T2D are <4% below 70 mg/dL and <1% below 54 mg/dL; for older adults, the below-70 mg/dL goal is <1%. Review these targets alongside individual risk and treatment burden.
CGM Across Insulin and Non-insulin Therapy
The module extends CGM review beyond insulin dosing to behavior change, pattern recognition, and therapy optimization in non-insulin-treated type 2 diabetes. It also considers titration support and residual hyperglycemia during GLP-1 receptor agonist therapy.
AGP review can inform patient coaching and medication assessment through:
Fasting and overnight trends relevant to basal insulin review.
Post-meal excursions and meal-related behavior.
Residual hyperglycemia during GLP-1 receptor agonist treatment.
Hypoglycemia patterns that may prompt treatment de-escalation.
Janice's case illustrates stopping glipizide, reviewing basal insulin, and introducing semaglutide with subsequent insulin discontinuation. The follow-up pattern is illustrative and requires the full clinical context.
AID Components and Hybrid Use
AID combines CGM data, a control algorithm, and an insulin pump. The deck discusses use in type 1 and insulin-treated type 2 diabetes, candidate selection, and transitions between AID and multiple daily injections, or MDI. Continuing CGM during time off AID supports ongoing pattern review.
Hybrid systems still require meal bolus attention. Jessica's case first addresses bolus timing, then persistent post-meal hyperglycemia with insulin-to-carbohydrate ratio adjustment. Her tuned-AID example is not an expected result for every person or every day.
Automated Dose Guidance Workflow
Dose guidance tools include insulin titration recommendations, bolus calculators, and decision support. Inputs include TIR, glucose management indicator or GMI, fasting trends, hypoglycemia flags, and current insulin dosing. Recommendations are distinct from automated insulin delivery.
The source supports this practical review sequence:
Review CGM patterns and current insulin dosing; assess hypoglycemia and clinical context; evaluate the recommendation with safety checks and clinician oversight; then monitor and reassess the response.
Gary's case considers basal insulin guidance because he lacks confidence in self-titration but is comfortable with technology. The guidance examples include safety checks and follow-up, and explicitly state that recommendations do not replace clinical judgment.
Practical Safety Considerations
Automation does not remove the need to review behavior, insulin delivery, changing clinical circumstances, and medication safety. The module highlights five considerations when interpreting patterns or changing therapy.
Meal bolus timing: Missed boluses can prolong post-meal hyperglycemia; late boluses may combine with algorithm-driven insulin and lead to later hypoglycemia.
Infusion site problems: Kinking or occlusion can interrupt insulin delivery. An AID algorithm cannot overcome a failed infusion site.
Changing clinical context: Dosing learned from historical insulin and CGM data may be inappropriate during illness or recovery when insulin needs change.
Hypoglycemia and treatment burden: Review low-glucose patterns, individual goals, and treatment burden when considering medication reduction or transitions between regimens.
Clinician oversight: Dose limits and other guardrails help prevent overcorrection. Clinicians remain involved in overall management and significant medication changes.
Core Concepts to Recall
Use these five points to review the module's clinical decision framework:
Review TIR, TBR, fasting and post-meal patterns alongside A1C, individual risk, and treatment burden.
AID connects CGM, an algorithm, and a pump, but hybrid use still requires meal boluses and reliable infusion sites.
CGM can inform coaching and therapy review beyond insulin use, including during GLP-1 receptor agonist treatment.
Dose guidance recommendations require current glucose and insulin data, safety checks, and clinician oversight.
Reassess therapy as patterns or clinical circumstances change; case examples are not universal dosing protocols.
Bibliography
Adolfsson P, Parkin CG, Thomas A, Krinelke LG. Selecting the Appropriate Continuous Glucose Monitoring System - a Practical Approach. Eur Endocrinol. 2018;14(1):24-29.
American Diabetes Association Professional Practice Committee for Diabetes*; 7. Diabetes Technology: Standards of Care in Diabetes—2026. Diabetes Care. 2026;49(Supplement_1):S150–S165.
Battelino T, Danne T, Bergenstal RM, et al. Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range. Diabetes Care. 2019;42(8):1593-1603.
Beck RW, Riddlesworth T, Ruedy K, et al; DIAMOND Study Group. Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial. JAMA. 2017;317(4):371-378.
Brown RE, Chu L, Norman GJ, Abitbol A. Real-world glycaemic outcomes in adult persons with type 1 diabetes using a real-time continuous glucose monitor compared to an intermittently scanned glucose monitor: A retrospective observational study from the Canadian LMC diabetes registry (REAL-CGM-T1D). Diabet Med. 2022;39(11):e14937.
Davis GM, Peters AL, Bode BW, et al. Glycaemic outcomes in adults with type 2 diabetes over 34 weeks with the Omnipod® 5 Automated Insulin Delivery System. Diabetes Obes Metab. 2025;27(1):143-154.
Dowd R, Jepson LH, Green CR, et al. Glycemic Outcomes and Feature Set Engagement Among Real-Time Continuous Glucose Monitoring Users With Type 1 or Non–Insulin-Treated Type 2 Diabetes: Retrospective Analysis of Real-World Data. JMIR Diabetes. 2023;8:e43991.
Gavin JR, Bailey CJ. Real-World Studies Support Use of Continuous Glucose Monitoring in Type 1 and Type 2 Diabetes Independently of Treatment Regimen. Diabetes Technol Ther. 2021;23(3_suppl):S-19-S-27.
Lind M, Polonsky W, Hirsch IB, et al. Continuous Glucose Monitoring vs Conventional Therapy for Glycemic Control in Adults With Type 1 Diabetes Treated With Multiple Daily Insulin Injections: The GOLD Randomized Clinical Trial. JAMA. 2017;317(4):379–387.
Martens T, Beck RW, Bailey R, et al. Effect of Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes Treated With Basal Insulin: A Randomized Clinical Trial. JAMA. 2021;325(22):2262–2272.
Miller EM. Using Continuous Glucose Monitoring in Clinical Practice. Clin Diabetes. 2020;38(5):429-438.
Oser T, et al. CGM for Adults with Type 2 Diabetes Not on Insulin: The CONNECT Randomized Controlled Trial. Presented at the 2026 Scientific Sessions of the American Diabetes Association, June 6, 2026. New Orleans, LA; USA.
Oskarsson P, Antuna R, Geelhoed-Duijvestijn P, et al. Impact of flash glucose monitoring on hypoglycaemia in adults with type 1 diabetes managed with multiple daily injection therapy: a pre-specified subgroup analysis of the IMPACT randomised controlled trial. Diabetologia. 2018;61(3):539-550.
Pratley RE, Kanapka LG, Rickels MR, et al; Wireless Innovation for Seniors With Diabetes Mellitus (WISDM) Study Group. Effect of Continuous Glucose Monitoring on Hypoglycemia in Older Adults With Type 1 Diabetes: A Randomized Clinical Trial. JAMA. 2020;323(23):2397-2406.
Sherr JL, Heinemann L, Fleming GA, et al. Automated insulin delivery: benefits, challenges, and recommendations. A Consensus Report of the Joint Diabetes Technology Working Group of the European Association for the Study of Diabetes and the American Diabetes Association. Diabetologia. 2023;66(1):3-22.
van Beers CA, DeVries JH, Kleijer SJ, et al. Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial. Lancet Diabetes Endocrinol. 2016 ;4(11):893-902.
Additional Resources
Association of Diabetes Care & Education Specialists. CGMs in Professional Practice. Available at: https://www.adces.org/education/danatech/glucose-monitoring/continuous-glucose-monitors-(cgm)/cgms-in-professional-practice. Accessed July 8, 2026.
Simonson GD, Holt EH, Grady M, et al. Unleashing the Potential of Blood Glucose Monitoring Data With the Ambulatory Glucose Profile Report. Clin Diabetes. 2024;42(4):550-560.